日本 SATO 温度計 / 濕度計 / 氣壓計
|
|
品牌
|
圖片
|
型號 , 特點
, 備註
|
|
|
|
1.
|
SATO
No. 8260-00
Mini Infrared Thermometer Model SK-8700
小型紅外線測温儀
|

|
| Model |
SK-8700 |
| Measuring range |
-20°C to 420°C (0 to 786°F) |
Accuracy |
± 2°C at -20°C to 100°C |
| ± 2% Reading at 101°C to 420°C |
| (conditions) |
Ambient
temperature at 23°C ± 5°C
calibrated by black body emissivity at 0.95 |
| Resolution |
1°C / 1°F |
| Repeatability |
±1°C / ± 1°F |
| Emissivity (*1) |
Fixed at 0.95 |
Distance to spot ratio
(*2) |
8 : 1 |
| Sensor |
Thermopile |
| Spectral response (*3) |
6 to 14μm |
| Response time |
0.5 second |
| Laser sighting |
1 point, Class II Laser (use less than 1mW of power) |
| Operating ambient |
0 to 50°C for temperature
less than 80% for R. humidity (no condensing) |
| Storage ambient |
-20 to 55°C for temperature
less than 90% for R. humidity (no condensing) |
| Power requirement |
9V battery x 1 (included) |
| Power consumption |
Max. 40mA (when Laser and Backlight ON) |
| Battery Life |
approx. 5 hours (Laser & Backlight ON)
approx. 10 hours (Laser ON & Backlight OFF)
approx. 12 hours (Laser OFF & Backlight ON)
approx. 50 hours (Laser & Backlight OFF) |
| Functions |
°C/°F selectable
Backlight ON/OFF
Laser marker ON/OFF
Auto power off |
| Dimensions |
(W) 41.5 x (D) 65 x (H) 160 mm |
| Weight |
approx. 140 g (with battery) |
|
(*1) Emissivity:
An object's ability to emit or absorb energy. Perfect emitters have an
emissivity of 1. An object with emissivity of 0.8 absorbs 80% and
reflects 20% of the incidental energy. Emissivity may vary with
temperature and spectral response (wavelength).
|
|
(*2) Distance to spot size ratio
(D:S)
The infrared thermometer focuses infrared energy form an object onto
its detector at the rate. 8:1 distance to spot ratio means that the
infrared thermometer will read 10cm diameter area 80cm away. For higher
accuracy, make sure the area of the object is at least twice as large
as the spot being measured
|
|
|
|
|
2.
|
SATO
No. 8062-00
Waterproof Digital Thermometers
防水型數顯式温度計
SK-250WP II -N
|

|
| Model |
SK-250WP
II Waterproof Digital Thermometers |
| Measuring
range |
-55°C to
305°C
|
Accuracy
|
±0.1°C
== at
-9.9°C to 199.9 °C
±1°C == at other than above
|
| Waterproof
properties |
conforming to JIS
C 0920 Protection class 6 (equivalent to IP X6) |
| Operation
ambient |
0 to 50°C |
Display
samplling
|
about
1 sec
|
| Power
requirements |
3VDC ("AAA"
size battery x2) |
| Battery
life |
about 1000 hours
continuous (by using alkaline batteries) |
| Dimensions |
71(W) x 170 (H)
x 36 (D) mm |
| Weight
(body) |
approx. 145g
(inclusive batteries) |
| Materials |
ABS resin |
| Standard
accessories |
SWP II-01 probe
with test result, hand strap, vinyl cover,
"AAA" size alkaline battery x 2
|
|
|
|
|
3.
|
Sigma II Thermohygrograph
(-15 to 40°C, 0 to 100%)
自記温濕度記錄儀
SIGMA II - NSII-Q
cat no. : 7210-00
|

|
Our long-run bestseller
with reliable accuracy. This precision instrument is functionally
designed to answer to various needs.
(Measuring Range : -15 to 40°, 0 to 100%)
|

| Model |
NSII-Q
(Quartz type) |
| Clock |
Quartz
clock: 1 day, 7 day and 32 day changed by speed switch
Battery: "C" size battery x 2
Life of battery: 1 year for continuous use |
| Sensors |
Aged
bimetal strip for temperature
Human hair bundle for relative humidity |
| Measuring
range |
-15
to 40°C for temperature
0 to 100% for R. humidity |
| Accuracy |
±1°C
(at 10 to 30°C) for temperature
±2°C (at other than above) for temperature
±3% (at 15 to 25°C, 20 to 95%) for R. humidity
±5% (at other than above) for R. humidity |
| Chart graduation |
1°C
for temperature
1% for R. humidity |
| Recording pens |
Cartridge
pens (violet) |
| Dimensions |
(W)336
x (H)295 x (D)148 mm |
| Weight |
approx.
3.1 kg |
| Accessories |
7-day
chart for 1 year use (55 sheets/pad)
chart holder
"C" size battery x 2 |
Consumables
- No. 7210-60 1-day chart, range -15/40°C,
0-100%
(400 sheets/pad) Dustproof type
- No. 7210-62 7-day chart, range -15/40°C,
0-100%
(55 sheets/pad) Dustproof type
- No. 7210-64 32-day chart, range -15/40°C,
0-100% (55 sheets/pad) Dustproof type
- No. 7210-90 Spare cartridge pen (violet)
- No. 7210-92 Spare cartridge pen (red)
- No. 7210-20 Axial AC fan in 100/110VAC use
|
|
|
|
|
4.
|
Sigma II Barograph
自記氣壓記錄儀
Cat. No. 7237-00
Model NSII-BQ
|

|
Cat. No.
7237-00
Model NSII-BQ
The instrument to measure and record air pressure.
One box of 7-day charts (940 to 1045 hPa) for one year use included.

| Model |
NSII-BQ |
| Clock |
Quartz
type
Battery life: about 1 year in continuous use |
| Drum rotation |
1
day, 7 day and 32 day changed by speed switch |
| Sensor |
Aneroid
bellows |
Temperature
compensation |
Bimetal
strip |
| Measuring range |
940
to 1045hPa |
| Accuracy |
±1
hPa at 950 to 1040 hPa
±2 hPa at other than above |
| Chart graduation |
1 hPa |
| Recording pen |
Cartridge
pen (violet) |
| Dimensions |
(W)336
x (H)295 x (D)148 mm |
| Weight |
approx.
3.1 kg |
| Accessories |
7-day
chart for 1 year use (55 sheets/pad), chart holder,
"C" size battery x 2 |
* Spring-wound type is also available.
Consumables
- No. 7237-60 Spare 1-day chart (400 sheets/pad)
- No. 7237-62 Spare 7-day chart (55 sheets/pad)
- No. 7237-64 Spare 32-day chart (55 sheets/pad)
- No. 7210-90 Spare cartridge pen (violet)
- No. 7210-92 Spare cartridge pen (red)
- No. 7210-20 Axial AC fan in 100/110VAC use
|
|
|
|
5.
|
Thermohygrograph
Model Mini-α (Mocha-brown)
Cat. No. 7006-10
小型自記温度記錄儀
|

|
A compact and lightweight
(approx. 800g) thermohygrograph. This instrument can be used as a
desktop or a wall-mount use.
|

| Model |
Mini-Alpha |
| Clock |
Quartz
type
"AA" size battery x 1
Battery life: about 6 months in continuous use |
| Drum
rotation |
7
day |
| Sensors |
Aged
bimetal strip for temperature
Humidity sensing coil for relative humidity |
| Measuring
range |
-15
to 50°C for temperature
10 to 100% for R. humidity |
| Accuracy |
±2°C
(at 10 to 30°C) for temperature
±3°C (at other than above) for temperature
±5% (at 15 to 25°C, 30 to 90%)for R. humidity
±7% (at other than above) for R. humidity |
| Chart
graduation |
2°C
for temperature,
5% for R. humidity |
| Recording
pens |
Cartridge
pens (violet) |
| Dimensions |
(W)125
x (H)185 x (D)110 mm |
| Weight |
approx.
0.8 kg |
| Accessories |
7-
day chart (55 sheets/pad)
"AA" size battery x 1, button cell battery (LR-41) x 1 for digital clock |
Consumables
- No. 7006-62 Spare 7-day chart (55 sheets/pad)
- No. 7210-90 Spare cartridge pen (violet)
- No. 7210-92 Spare cartridge pen (red)
|

|
|
|
|
6.
|
Thermohygrograph
Model Mini-Cube
Cat. No. 7008-00
小型自記温度記錄儀
|

|
Cat. No.
7008-00
This compact type thermohygrograph fits almost anywhere at your
convenience.
One box of 7-day charts included.
(Measuring range: -15 to 40°C 5 to 100%)
| Model |
Mini-Cube |
| Clock |
Quartz
type |
| Drum rotation |
7 day |
| Sensors |
Aged
bimetal strip for temperature
Human hair bundle for relative humidity |
| Measuring range |
-15
to 40°C for temperature
5 to 100% for R. humidity |
| Accuracy |
±2°C
(at 10 to 30°C) for temperature
±3°C (at other than above) for temperature
±5% (at 15 to 25°C, 30 to 90%) for R. humidity
±7% (at other than above) for R. humidity |
| Chart graduation |
2°C
for temperature
5% for R. humidity |
| Recording pens |
Cartridge
pen (violet) |
| Dimensions |
(W)148
x (H)190 x (D)97 mm |
| Weight |
approx.
1.6 kg |
| Accessories |
7-day
chart for 1 year use (55 sheets/pad), "AA" size battery x 1 |
Consumables
- No. 7008-62 Spare 7-day chart (55 sheets/pad)
- No. 7210-90 Spare cartridge pen (violet)
- No. 7210-92 Spare cartridge pen (red )
|
|
|
|